NovuSoft

Hardware

The hardware that keeps reading alive

However good the software is, the data comes off a line. The NovuSoft hardware family connects the M-Bus line to a laptop, a phone, the building's network or the mobile network — and all of it writes to the same panel and the same archive. Device choice follows the project's infrastructure; the table below shows what fits where.

Orders and quotes

How many blocks, how many units, which meter types — with that we recommend the right device in the right quantity. Fill in the form and we will come back with price and lead time.

Order form

Which one do I need

Comparison

Choosing a converter comes down to one question: how does the data leave the building? For permanent reading, the mobile network or the building's internet; for field reading, a phone or a laptop.
ProductConnectionInstallationLine capacityPrice
NVS Konverter USBUSBPortable · field3 standard M-Bus unit loads$96
NVS Konverter BTBluetoothPortable · field3 standard M-Bus unit loads$108
NVS Modem WiFiWi-FiFixed · in-panel20 standard M-Bus unit loads$144
NVS Modem 4.5G4.5G / LTEFixed · in-panel60 standard M-Bus unit loads$216
NVS Modem 2G2G / GPRSFixed · in-panel20 standard M-Bus unit loads$168
NVS RF Terminal868 MHz RF · USBPortable · field$240
NVS PowerBankDC 12 V / 24 VPortable · field$72

Prices are USD list prices. Orders shipped outside Türkiye are invoiced in USD and are VAT exempt as an export sale; customs duties and import taxes are the buyer's responsibility. Volume pricing applies on larger projects.

Why NovuSoft hardware

Hardware and software from one hand

When the converter comes from one supplier and the software from another, each blames the other the moment something breaks. Here the line, the device and the panel are one system — if a reading does not arrive, finding out why is our job.

One party to call

Silent modem, broken line or faulty meter — we make the distinction. Device and software support run from the same place.

Monitored from the panel

Last-seen time, signal level and M-Bus line voltage sit in the panel for every device. A modem that goes quiet shows on screen, not in a report.

Brand-independent reading

Our devices read standard M-Bus and wM-Bus telegrams. You do not have to replace the meters already installed.

Mixed fleet, one panel

2G, 4.5G, Wi-Fi and Bluetooth devices run side by side on the same project; archive and billing are identical for all of them.

Orders and quotes

Tell us what you need and we will quote it

How many blocks, how many units, which meter types — with that we recommend the right device in the right quantity. Fill in the form and we will come back with price and lead time.