Why NovuSoft

One chain, from reading to the bill

Most teams run two programs: one reads the meters, another calculates the bill. The handover between them costs both time and confidence. NovuSoft builds the whole chain in one panel.

What sets it apart

Six points

Each one corresponds to a screen or a field in the panel.

We do not ask you to replace your meters

Reading is based on the M-Bus protocol rather than a manufacturer's own software. Your installed heat and water meters stay where they are; what changes is how you read and bill them.

  • Protocol-level reading
  • Wired M-Bus and wireless wM-Bus
  • Mixed portfolio in one panel

The calculation follows the regulation

Measured consumption and floor area split, domestic hot water, minimum heating and estimation rules each correspond to a field in the panel — and we cite the basis.

  • Energy Efficiency Law 5627
  • Regulation 26847
  • Metrology Law 3516

The record carries evidence

Every reading keeps its source, timestamp and returned value in permanent storage. A remotely read index cannot be edited by hand — the correction path is deleting the record and entering a manual index.

  • Source: remote, app, Excel, manual
  • History of reading attempts
  • No inventory change without approval

Projects without modems run on the same system

Where there is no remote infrastructure, indexes are read on site and imported through Excel or the field app. The billing engine is the same, so you never maintain two programs.

  • One billing engine
  • Excel import and export
  • Field app included

Field work lives inside the panel

A meter that cannot be read remotely becomes a field task assigned from the same panel and closed in the same panel — and reading continues without a signal inside the building.

  • Offline index entry
  • Barcode and photo evidence
  • Excel reading report at round close

Permissions are the data model

The partner hierarchy is not a layer bolted on afterwards. Each partner sees only their own projects, and users reach only the projects they have been given.

  • Six roles
  • Partner-level isolation
  • Controlled access to personal data

Scope

The product at a glance

Verified against the product manual.
M-BUSwM-BUSLoRaWANRS-485REGULATION 26847
Modules
Nine modules; all open on every account
Meter types
Heat, hot water, cold water, electricity
Reading paths
M-Bus, wM-Bus, RF, LoRaWAN, RS-485 and the mobile field app
Roles
System, partner, project, block, field, resident
Outputs
Unit statement, posting list, checklist, Excel export